<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns="http://purl.org/rss/1.0/" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel rdf:about="http://dspace.univ-tiaret.dz:80/handle/123456789/116">
    <title>DSpace Collection:</title>
    <link>http://dspace.univ-tiaret.dz:80/handle/123456789/116</link>
    <description />
    <items>
      <rdf:Seq>
        <rdf:li rdf:resource="http://dspace.univ-tiaret.dz:80/handle/123456789/16993" />
        <rdf:li rdf:resource="http://dspace.univ-tiaret.dz:80/handle/123456789/16992" />
        <rdf:li rdf:resource="http://dspace.univ-tiaret.dz:80/handle/123456789/16991" />
        <rdf:li rdf:resource="http://dspace.univ-tiaret.dz:80/handle/123456789/16990" />
      </rdf:Seq>
    </items>
    <dc:date>2026-04-07T18:43:39Z</dc:date>
  </channel>
  <item rdf:about="http://dspace.univ-tiaret.dz:80/handle/123456789/16993">
    <title>Synthèse et caractérisation des films minces d’oxyde de structure spinelle ZnCo2O4 dopés Sn par le Procédé Sol-gel (Dip-coating)</title>
    <link>http://dspace.univ-tiaret.dz:80/handle/123456789/16993</link>
    <description>Titre: Synthèse et caractérisation des films minces d’oxyde de structure spinelle ZnCo2O4 dopés Sn par le Procédé Sol-gel (Dip-coating)
Auteur(s): SELLAMI, SAMIRA
Résumé: Dans le cadre de cette étude, des couches minces de ZnCo₂O₄, à la fois non dopées et dopées, ont été&#xD;
élaborées sur des substrats en verre de type Pyrex en utilisant une méthode combinée Sol-Gel et DipCoating. Les propriétés structurales, optiques et électriques de ces films ont été examinées à l’aide de&#xD;
plusieurs techniques de caractérisation, notamment la diffraction des rayons X, la spectroscopie UVVisible, la spectroscopie infrarouge, la spectroscopie d’impédance complexe .Les résultats de la&#xD;
diffraction des rayons X révèlent une structure cristalline avec une orientation préférentielle suivant le&#xD;
plan (220). L’analyse des spectres UV-Visible a permis de déterminer que le ZnCo₂O₄ possède un&#xD;
comportement semi-conducteur avec une bande interdite optique diminue progressivement en&#xD;
augmentant le taux de dopage. Les spectres infrarouges montrent des bandes d’absorption localisées&#xD;
autour de 674 cm⁻¹ et 580 cm⁻¹, attribuées respectivement aux vibrations d’élongation des liaisons&#xD;
Zn–O et Co–O. Par ailleurs, les mesures d’impédance complexe indiquent que le transport électrique&#xD;
est principalement influencé par les joints de grains, et que le comportement global peut être modélisé&#xD;
par un circuit équivalent de type RC en parallèle
Description: In this study, undoped and doped ZnCo₂O₄ thin films were grown on Pyrex glass substrates using a&#xD;
combined sol-gel and dip-coating method. The structural, optical, and electrical properties of these&#xD;
films were examined using several characterization techniques, including X-ray diffraction, UVVisible spectroscopy, infrared spectroscopy, complex impedance spectroscopy.&#xD;
X-ray diffraction results revealed a crystalline structure with a preferential orientation along the (220)&#xD;
plane. Analysis of UV-Visible spectra determined that ZnCo₂O₄ exhibits semiconducting behavior&#xD;
with an optical band gap that gradually decreases with increasing doping rate.. Infrared spectra show&#xD;
absorption bands located around 674 cm⁻¹ and 580 cm⁻¹, attributed to the stretching vibrations of the&#xD;
Zn–O and Co–O bonds, respectively. Furthermore, complex impedance measurements indicate that&#xD;
the electrical transport is mainly influenced by grain boundaries, and that the overall behavior can be&#xD;
modeled by a parallel RC equivalent circuit.</description>
    <dc:date>2025-06-25T00:00:00Z</dc:date>
  </item>
  <item rdf:about="http://dspace.univ-tiaret.dz:80/handle/123456789/16992">
    <title>Apprentissage profond pour la segmentation automatique des lésions tumorales dans les images Tomodensitométriques des poumons</title>
    <link>http://dspace.univ-tiaret.dz:80/handle/123456789/16992</link>
    <description>Titre: Apprentissage profond pour la segmentation automatique des lésions tumorales dans les images Tomodensitométriques des poumons
Auteur(s): Fedoul, Arbia; Nait Hamoud, Silina
Résumé: Cette étude explore l'utilisation de l'apprentissage profond pour la segmentation automatique&#xD;
des tumeurs pulmonaires à partir d'images tomodensitométriques (TDM). Nous proposons une&#xD;
architecture basée sur U-Net, enrichie d'un mécanisme d'attention, afin d'améliorer la précision&#xD;
de la détection des lésions tumorales. Le modèle a été entraîné et évalué sur la base de&#xD;
données Medical Segmentation Decathlon (MSD), comprenant des images TDM thoraciques&#xD;
annotées.&#xD;
Nos résultats démontrent une performance élevée, avec un coefficient de Dice de 0,88,&#xD;
une sensibilité de 0,87 et une précision de 0,92, surpassant plusieurs approches existantes.&#xD;
L'intégration d'un mécanisme d'attention permet au modèle de mieux cibler les régions tumorales,&#xD;
réduisant ainsi les faux positifs et améliorant la segmentation des lésions de petite taille.&#xD;
Cependant, certaines limitations persistent, notamment la complexité computationnelle des&#xD;
modèles 3D et la nécessité d'une validation sur des ensembles de données plus variés. Les&#xD;
perspectives futures incluent l'optimisation des architectures 3D, l'intégration de réseaux&#xD;
hybrides (CNN + Transformers) et l'application en temps réel pour la radiothérapie guidée par&#xD;
l'IA.&#xD;
Cette recherche contribue à l'avancement des outils d'aide au diagnostic en oncologie&#xD;
thoracique, offrant une solution prometteuse pour une détection précoce et une planification&#xD;
thérapeutique plus précise.
Description: This study explores the use of deep learning techniques for the automatic segmentation of lung&#xD;
tumors from computed tomography (CT) images. We propose an architecture based on U-Net,&#xD;
enhanced with an attention mechanism, in order to improve the accuracy of lesion detection. The&#xD;
model was trained and evaluated on the Medical Segmentation Decathlon (MSD) dataset, which&#xD;
includes annotated thoracic CT scans.&#xD;
Our results demonstrate high performance, achieving a Dice coefficient of 0.88, a sensitivity&#xD;
of 0.87, and a precision of 0.92, surpassing several existing approaches. The integration of an&#xD;
attention mechanism enables the model to more effectively target tumor regions, reducing false&#xD;
positives and enhancing the segmentation of small lesions. However, certain limitations remain, notably the computational complexity of 3D models&#xD;
and the need for validation on more diverse datasets. Future directions include optimizing 3D&#xD;
architectures, integrating hybrid networks (CNN + Transformers), and enabling real-time&#xD;
applications for AI-guided radiotherapy.&#xD;
This research contributes to the advancement of decision-support tools in thoracic oncology,&#xD;
offering a promising solution for early detection and more accurate therapeutic planning.</description>
    <dc:date>2025-06-29T00:00:00Z</dc:date>
  </item>
  <item rdf:about="http://dspace.univ-tiaret.dz:80/handle/123456789/16991">
    <title>Optimisation des paramètres d'acquisition en scanner et en IRM : Réduction de la dose de rayonnement et amélioration de la qualité d'image</title>
    <link>http://dspace.univ-tiaret.dz:80/handle/123456789/16991</link>
    <description>Titre: Optimisation des paramètres d'acquisition en scanner et en IRM : Réduction de la dose de rayonnement et amélioration de la qualité d'image
Auteur(s): Mekkari, Aya; Khanoudj, Khaoula
Résumé: Dans le souci de réduire les risques liés à l’exposition cumulative aux rayonnements&#xD;
ionisants, la réduction de dose en tomodensitométrie (TDM) s’impose de plus en plus comme&#xD;
une pratique courante, notamment chez les patients soumis à des examens répétitifs. Toutefois,&#xD;
cette diminution de dose entraîne une dégradation notable de la qualité des images, caractérisée&#xD;
essentiellement par l’augmentation du bruit. Ce travail s’inscrit dans une démarche&#xD;
d’amélioration de la qualité des images TDM à faible dose à travers l’évaluation de différentes&#xD;
techniques de débruitage. Un bruit gaussien simulé a été introduit sur des images originales, et&#xD;
six méthodes ont été étudiées : les filtres moyen, médian, et Wiener, la décomposition en&#xD;
ondelettes , une approche de reconstruction itérative, ainsi que le modèle DnCNN basé sur&#xD;
l’apprentissage profond. L’analyse des performances, réalisée à l’aide des métriques PSNR,&#xD;
SSIM et MSE, a révélé que la combinaison du réseau DnCNN avec le filtre médian permet&#xD;
d’atteindre un bon équilibre entre réduction du bruit et préservation des structures anatomiques.&#xD;
Ces résultats mettent en évidence la pertinence des approches fondées sur l’intelligence&#xD;
artificielle dans le contexte de l’optimisation des protocoles d’imagerie à faible dose.
Description: To minimize the cumulative effects of ionizing radiation, low-dose protocols in&#xD;
computed tomography (CT) have become increasingly common, particularly in cases requiring&#xD;
frequent imaging. However, reducing the dose often comes at the expense of image quality,&#xD;
primarily due to increased noise levels. This work aims to evaluate and compare various&#xD;
denoising techniques to restore the diagnostic quality of low-dose CT images. Simulated&#xD;
Gaussian noise was added to original CT scans, and six approaches were tested: mean filter,&#xD;
median filter, Wiener filter, Daubechies wavelet transform, iterative reconstruction, and&#xD;
DnCNN—a deep learning model. Quantitative evaluation based on PSNR, SSIM, and MSE&#xD;
metrics shows that the combination of DnCNN and the median filter yields the best&#xD;
compromise between noise suppression and structural detail preservation. These findings&#xD;
highlight the significant potential of deep learning in supporting safer imaging practices&#xD;
without compromising diagnostic reliability.</description>
    <dc:date>2025-06-29T00:00:00Z</dc:date>
  </item>
  <item rdf:about="http://dspace.univ-tiaret.dz:80/handle/123456789/16990">
    <title>ab-initio and experimental investigations of the physical properties of cobalt Sulfides</title>
    <link>http://dspace.univ-tiaret.dz:80/handle/123456789/16990</link>
    <description>Titre: ab-initio and experimental investigations of the physical properties of cobalt Sulfides
Auteur(s): SAFA, SARA
Résumé: This work used both computational and experimental techniques to investigate different&#xD;
cobalt sulphide phases. In this study preconceived notions about the magnetic properties of&#xD;
compounds CoS₂ and discovered metallic and half-metallic behaviour of the several phases&#xD;
through Quantum ESPRESSO simulations. Co₉S₈ was synthesised experimentally with a&#xD;
hexagonal structure and a particle size of about 22 nm. It demonstrated an indirect band gap&#xD;
and more than 60% optical transmittance. These results provide important new information&#xD;
about the potential uses of cobalt sulphides in solar cells, energy storage, catalysis, and&#xD;
medicine</description>
    <dc:date>2025-06-30T00:00:00Z</dc:date>
  </item>
</rdf:RDF>

